Computer Automation Technology
Fort Lauderdale, Florida
CAT Note
22
Release Date: June 14, 2008

Connecting a CAT to a Kenwood
TKR-720 or TKR-820.


Connecting a CAT controller to a Kenwood TKR-720 or TKR-820 Repeater can be accomplished easily by following these steps.

Build a interconnect cable with a DB-25 male connector on one end and a 15 pin Molex connector on the other end. (Note: a pre-built cable can be special ordered from CAT).

Note: Install a 2200 ohm pull-up resistor on the controller board at the COR #1 position. Set dip-switch #1 to the ON position for an active low COR.

Connector is a male Molex catalog #1625-15PRT (.062 inch pin spacing)

 

This site is best viewed with Internet Explore 5.0 and above or Netscape 6.0 and above.

Computer Automation Technology, Inc.
4631 N.W. 31st Avenue, Suite 142
Fort Lauderdale, Florida 33309

Main Office Number

Send mail to Webmaster with questions or comments about this web site.