CAT Repeater Controller
Frequency Response Plots

   

  Test Procedure:
  Figure 1 shows the test set-up used. A constant voltage of 200mv RMS was maintained from the waveform generator and applied to the receiver #1 input of each controller across all frequencies. The receiver level was adjusted for a internal audio bus level of 200mv. The output level (TX#1) was first adjusted for a 0dB reading at 1000Hz on the distortion analyzer as a reference point. Readings were then plotted between 100Hz and 10KHz (see charts below for each controller). Distortion measurements were noted and charted at 100, 500, 1,000, 5,000, and 10,000 Hertz. Units under test were pulled randomly from finish-goods stock.
     
 

 


Figure 1  Test Set-Up

 
     
 

     
     
 

     
 

     
 

     
 
   
   
   

Repeater Controller
Audio Distortion

 
  CAT200 CAT-250 CAT-300 CAT-300DXL CAT-700 CAT-1000
100 Hz 2.5% 1.5% < 1% 2.0% 1.75% < 1%
500 Hz 1.75% 1.2% < 1% 1.5% 1.5% < 1%
1,000 Hz 1.5% 1.2% < 1% 1.5% 1.5% < 1%
5,000 Hz 1.5% 1.5% < 1% 1.5% 1.5% < 1%
10,000 Hz 1.75% 1.5% < 1% 1.75% 1.75% 1%
 

This site is best viewed with minimum Internet Explore 5.0, Netscape 6.0, and Firefox 2.0.

Computer Automation Technology, Inc.
4631 N.W. 31st Avenue, Suite 142
Fort Lauderdale, Florida   33309
CAT Main Office Number

Send mail to Webmaster with questions or comments about this web site.

Copyright © 2003-2007 www.catauto.com. All rights reserved.